For Clinicians – A General Introduction and Guide to OpenAPS¶
This page is intended for clinicians who have expressed interest in open source artificial pancreas technology such as OpenAPS, or for patients who want to share such information with their clinicians.
This guide has some high-level information about DIY closed looping and specifically how OpenAPS works. For more details on all of these topics, please view the comprehensive OpenAPS documentation online. If you have questions, please ask your patient for more details, or always feel free to reach out to the community with question. (If you’re not on social media (e.g. Twitter or Facebook), feel free to email Dana@OpenAPS.org). You can also find some of the latest studies & outcomes related data here.
The steps for building a DIY Closed Loop:¶
When someone builds an OpenAPS rig, the steps are generally to:
- physically put the pieces of the rig together
- load the open source software on it
- configure it to talk to their diabetes devices and specify settings and safety preferences
How A DIY Closed Loop Works¶
Without a closed loop system, a person with diabetes gathers data from their pump and CGM, decides what to do, and takes action.
With automated insulin delivery, the system does the same thing: it gathers data from the pump, CGM, and anywhere else information is logged (such as Nightscout), uses this information to do the math and decide how much more or less insulin is needed (above or below the underlying basal rate), and uses temporary basal rates to make the necessary adjustments to keep or eventually bring BGs into target range.
If the rig breaks or goes out of range of the pump, once the latest temporary basal rate ends, the pump falls back to being a standard pump with the usual basals runnning.
How data is gathered:¶
With OpenAPS, there is a “rig” that is a physical piece of hardware. It has “brains” on the computer chip to do the math, plus a radio chip to communicate with the pump. It can talk to a phone and to the cloud via wifi to gather additional information, and to report to the patient, caregivers, and loved ones about what it’s doing and why.
The rig needs to:
- communicate with the pump and read history - what insulin has been delivered
- communicate with the CGM (either directly, or via the cloud) - to see what BGs are/have been doing
The rig runs a series of commands to collect this data, runs it through the algorithm and does the decision-making math based on the settings (ISF, carb ratio, DIA, target, etc.) in your pump.
It will also gather any information about boluses, carbohydrate consumption, and temporary target adjustments from the pump or from Nightscout.
How does it know what to do?¶
The open source software is designed to make it easy for the computer to do the work people used to do (in manual mode) to calculate how insulin delivery should be adjusted. It first collects data from all the devices and from the cloud, prepares the data and runs the calculations, makes predictions of what BGs will be expected to do in different scenario, and calculates the needed adjustments to keep or bring BG back into target range. Next it attempts to communicate and send any necessary adjustments to the pump. Then it reads the data back, and does it over and over again.
OpenAPS is designed to transparently track all input data it gathers, the resulting recommendation, and any action taken. It is therefore easy to answer the question at any time, “why is it doing X?” by reviewing the logs.
Examples of OpenAPS algorithm decision making:¶
OpenAPS makes multiple predictions (based on settings, and the situation) representing different scenarios of what might happen in the future. In Nightscout, these are displayed as “purple lines”. In the logs, it will describe which of these predictions and which time frame is driving the necessary actions.
Here are examples of the purple prediction lines, and how they might differ:¶
Here are examples of different time frames that influence the needed adjustments to insulin delivery:¶
Scenario 1 - Zero Temp for safety¶
In this example, BG is rising in the near-term time frame; however, it is predicted to be low over a longer time frame. In fact, it is predicted to go below target and the safety threshold. For safety to prevent the low, OpenAPS will issue a zero temp, until the eventualBG (in any time frame) is above threshold.
Scenario 2 - Zero temp for safety¶
In this example, BG is predicted to go low in the near-term, but is predicted to eventually be above target. However, because the near-term low is actually below the safety threshold, OpenAPS will issue a zero temp, until there is no longer any point of the prediction line that is below threshold.
Scenario 3 - More insulin needed¶
In this example, a near-term prediction shows a dip below target. However, it is not predicted to be below the safety threshold. The eventual BG is above target. Therefore, OpenAPS will restrain from adding any insulin that would contribute to a near-term low (by adding insulin that would make the prediction go below threshold). It will then assess adding insulin to bring the lowest level of the eventual predicted BG down to target, once it is safe to do so. (Depending on settings and the amount and timing of insulin required, this insulin may be delivered via temp basals or SMB’s).
Scenario 4 - Low temping for safety¶
In this example, OpenAPS sees that BG is spiking well above target. However, due to the timing of insulin, there is already enough insulin in the body to bring BG into range eventually. In fact, BG is predicted to eventually be below target. Therefore, OpenAPS will not provide extra insulin so it will not contribute to a longer-timeframe low. Although BG is high/rising, a low temporary basal rate is likely here.
Optimizing settings and making changes¶
As a clinician who may not have experience with OpenAPS or DIY closed loops, you may find it challenging to help your patient optimize their settings or make changes to improve their outcomes. We have multiple tools and guides in the community that help patients make small, tested adjustments to improve their settings.
The most important thing for patients to do is make one change at a time, and observe the impact for 2-3 days before choosing to change or modify another setting (unless it’s obviously a bad change that makes things worse, in which case they should revert immediately to the previous setting). The human tendency is to turn all the knobs and change everything at once; but if someone does so, then they may end up with further sub-optimal settings for the future, and find it hard to get back to a known good state.
One of the most powerful tools for making settings changes is an automated calculation tool for basal rates, ISF, and carb ratio. This is called “Autotune”. It can also be run independently/manually, and allow the data to guide you or your patient in making incremental changes to settings. It is best practice in the community to run (or review) Autotune reports first, prior to attempting to make manual adjustments to settings.
Additionally, human behavior (learned from manual diabetes mode) often influences outcomes, even with a DIY closed loop. For example, if BG is predicted to go low and OpenAPS reduces insulin on the way down, only a small amount of carbs (e.g. 3-4 carbs) may be needed to bring BG up from 70. However, in many cases, someone may choose to treat with many more carbs (e.g. sticking to the 15 rule), which will cause a resulting faster spike both from the extra glucose and because insulin had been reduced in the timeframe leading up to the low. One feature that aids patients in making behavior changes as they transition to DIY closed loops is to set up Pushover, an app that enables them to get push alerts from the rig that specify if carbs are needed, and if so, how many. They can then make an informed decision about carbs needed to adjust for the BG, and this data is helpful for understanding the cause and effect between the amount of low treatment and the resulting BG levels after that.
Summary¶
This is meant to be a high-level overview of how OpenAPS works. For more details, ask your patient, reach out to the community, or read the full OpenAPS documentation available online.
Additional recommended reading:
- The OpenAPS Reference Design, which explains how OpenAPS is designed for safety: https://openaps.org/reference-design/
- The full OpenAPS documentation